-40%

Omron Timer H3CA-A Digital 24-240 volt USED Good Working Condition

$ 50.16

Availability: 100 in stock

Description

Omron Timer H3CA-A digital 24-240 volt
List price is per timer.
Rated supply voltage
24 to 240 VAC
12 to 240 VDC
Time range
0.1 s to 9990 h
Input method
No-voltage input (open and short-circuit)
Control output
Time-limit contact: SPDT
Display method
LCD 3 digit
External connection method
11-pin round socket
Rated supply voltage
24 to 240 VAC (50/60 Hz)
12 to 240 VDC (Ripple 20% max. (Single-phase full-wave rectified power sources may be used for 24 to 240 VDC.))
Operating voltage range
90 to 110% of rated supply voltage (21.6 to 264 VAC/10.8 to 264 VDC)
Power consumption
Approx. 0.2 to 4 VA/Approx. 0.2 to 2 W
Time ranges(Number of ranges)
7
Time ranges
0.1 to 99.9 s
1 to 999 s
0.1 to 99.9 min
1 to 999 min
0.1 to 99.9 h
1 to 999 h
10 to 9990 h
Input method
No-voltage input (open and short-circuit)
Output modes
A: ON delay
B: Repeat cycle
C: Signal ON/OFF delay
D: Signal OFF delay
E: Interval
F: One shot and flicker
G: Signal ON/OFF delay
H: Signal OFF delay
Control output (Contact output)
Time-limit contact: SPDT
Resistive load: 3 A at 250 VAC
Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Reset system
Self-reset/External reset
Power reset
Reset time: 0.5 s max.
Display method
LCD 3 digit
Ambient temperature (Operating)
-10 to 55℃ (with no icing)
Ambient humidity (Operating)
35 to 85%
Accuracy of operating time
±0.3% ±0.05 s (The values are based on the set value.)
Setting error
±0.5% ±0.05 s (The values are based on the set value.)
Influence of voltage
±0.3% ±0.05 s (The values are based on the set value.)
Influence of temperature
±0.3% ±0.05 s (The values are based on the set value.)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min
Between control output terminals and operating circuit: 2000 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
Impulse withstand voltage
Between power terminals: 5 kV
Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Vibration resistance
Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistance
Destruction: 1,000 m/s**2, 3 times each in 6 directions
Malfunction: 100 m/s**2, 3 times each in 6 directions
Life expectancy
Electrical: 100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h)
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Degree of protection
IP40
Mounting method
Flush mounting / Surface mounting
External connection method
11-pin round socket
Applicable socket
P2CF-11, P2CF-11-E, P3GA-11, PL11
Accessory (sold separately)
Soft Cover: Y92A-48D
Hard Cover: Y92A-48B
Flush mounting adapter: Y92F-30/Y92F-70/Y92F-71
Weight
Approx. 110 g